Blog

Content of IEC 61284:1997 Overhead lines – Requirements and tests for fittings

International standard IEC 61284:1997 “Overhead lines – Requirements and tests for fittings” has defined requirements and test methods of electrical fittings (line hardware) for overhead lines. The complete IEC standard includes English and French language version, it’s too long and a little difficult for quick explore. Here we quote the content of IEC 61284 for […]

Insulator testing machines, Overhead line fittings

Routine tests of composite insulator with voltage greater than 1000V in IEC 61109 2008

Last time we talked about sample test of silicone composite insulator for AC system above 1KV, the IEC 61109:2008 has defined it clearly. Today let’s the coming section”routine test” of polymeric insulator in this IEC 61109: 13 Routine tests 13.1 Mechanical routine test Every insulator shall withstand, at ambient temperature, a tensile load at RTL […]

Insulator testing machines, Polymer insulators

Sample test method and rules of suspension and tension composite insulator in IEC 61109:2008

Sample test is a major method of insulator acceptance inspection for mass production. It is widely used by inspectors of insulators from manufacturers, power girds and electrical laboratories. Here we have definition, rules, test method and acceptance criteria of composite insulator of suspension type and tension type of international standard IEC 61109:2008 “spension and tension […]

Polymer insulators

Damage limit proof test and test of the tightness of the interface between end fittings and insulator housing in IEC61109:2008

Damage limit proof test and test of the tightness of the interface between end fittings and insulator housing,these two tests are two of the most important test in inspection process of composite insulator. Here is how international standard IEC 61109:2008 “Suspension and tension insulators for AC system with a nominal voltage greater than 1000V” defines these 2 […]

Insulator testing machines, Polymer insulators

Insulators tested in vertical position and horizontal position

As we know,high voltage insulators shall subject to mechanical failing load test, and when we mention “test in vertical position and horizontal position”, this more refer to suspension insulator, tension insulator, post insulator and pin insulator. The suspension and tension insulator are normally tested in horizontal direction, as they are long in shape, with length […]

Insulator testing machines, Overhead line insulators, Polymer insulators

End fitting of railway insulator of Indian market

End fitting of railway insulator of Indian market The end fittings of silicone composite insulator for 25KV railway overhead traction have specific requirements. The end fittings shall be made of spheroidal graphite cast iron to grade: 400/15 of IS:1865-1991 or forged steel fittings to BS-970(Part-II). Approval of the type test of the insulator implies employment […]

Insulator testing machines, Overhead line fittings, Polymer insulators

Mechanical failing load tester for insulator(Cantilever & Tension)

Name:Mechanical failing load tester for insulator (Cantilever & Tension) Other name: Cantilever/Tension failing load tester for ceramic/polymeric/glass insulator Introduction: This Mechanical failing load tester is designed to do type test and sample test on high voltage electrical insulators,  testing their mechanical performance of cantilever failing load and tensile failing load. It is also called bending testing machine sometimes for […]

Insulator testing machines

Crimping machine for composite insulator flange

What is crimping machine? Crimping machine is a kind of machine used to crimp the bottom flange of high voltage insulators in insulator production. With high pressure from hydraulic power force, crimping machine press the metallic flange from all direction and make the metal fittings (flange) well attach the core of composite insulators. Crimping machine is also […]

Insulator producting machine